Tag Archives: Earth Tube

Earth Tubes as Part of a Home HVAC System

4

Posted on November 27, 2012 by

Earth to Air Heat Exchangers (or Earth Tubes if you want to sound less scientific about it) are really only part of your home HVAC system.  In an ideal world, the Earth Tubes would heat/cool and dehumidify all the air you would need for your home via passive means.   In reality, you are going to need fans to augment the air flow and the air coming from your earth tubes is likely to need some additional dehumidification.  It may also be a good idea to mix it with “return” air as part of your whole home circulation.  You may want to add filters, heating/cooling coils, etc.  In some ways, the rest of the HVAC system would be like a normal home, but it could all be sized much smaller due to the advantages of drawing the intake air thru the earth tubes.

Here we explore some of the considerations and adjustments that may be needed when combining earth tubes with more traditional HVAC solutions.

 

Dehumidification

One of the main concerns about underground living is cool walls leading to condensation of humid air and, eventually, unhealthy mold.  Hot humid outside air drawn directly into an earth shelter will condense on the cool interior surfaces.  However, if the air is drawn in thru cool earth tubes, the condensation can happen there instead.  Of course, you don’t want mold in the earth tubes either, which is why you want them made out of nice smooth HDPE pipe and sloped to carry the water away.

If the temperature outside is a balmy 95°F with a Relative Humidity (RH) of 100% and it passes thru a 60°F tube, the cooler air can not hold as much moisture even as it maintains the same relative humidity.  Once it enters the home, it is mixed with other air and warms up to 70°F.  Since the temperature has now increased, the RH is only 70%, which is much better than outside, but still a bit high for comfort.   If the earth tube temperature was only 51°F and then the air was allowed to warm back up to 70°F, the RH would only be 50%.   This idea of dipping the temperature of the air as low as possible to force the water out of it, and then raising the temperature back up again is precisely why Air Conditioning (AC) units are so good at dehumidification.   They usually drop the entering air temperature well below the comfort level in order to force the moisture out of it before it enters the home and mixes with the “return air” to warm up again.   Note, these units do not attempt to cool and reheat all the air, only the entering air is cooled and it is then mixed with the warmer air that we are trying to cool.   When humidification is wanted without cooling, the evaporator and condenser are both placed in the flow.  The evaporator reduces the temperature of the air, condensation is drained off and then the condenser uses the heat it just removed upstream to warm the air right back up again.   This is all a lot easier if you dehumidify the air as it enters the home because you have less volume to worry about, so be sure to dehumidify before mixing with the return air that you are re-circulating thru your home.

 

Fans

Fans are needed to help move air around for ventilation or other reasons.  If you are using a forced air heat system, you will need larger fans to transport the heated air thru the home and then return much of it to the furnace to be “reheated” and used again.

Most forced air HVAC systems for above ground homes use 85% return air and only 15% fresh air.   I plan to use radiant floor heating, so my fan requirements will be significantly lower, my house will be quieter, less dusty, etc.

 

 

(more to come)

Earth Tube Design

Posted on August 10, 2012 by

Earth Tube Design

Earth tubes (also known as Earth-Air Heat Exchangers, EAHX in professional circles, or as “Cool Tubes” in Australia, or by a variety of other names) can be designed many ways.  Most home owners who install them realize that, while they are dealing with very ancient and intuitive technology, Earth Tubes are still poorly understood and somewhat “experimental”.  While specific performance data is somewhat lacking, there are many experts with their own rules of thumb…  Here I will try to sort it all out.

Since I plan to invest thousands of dollars in my own Earth-Air Heat Exchangers (a more sophisticated term than Earth Tubes), I have done a lot of research in order to try and optimize my designs.  I have found that there are a wide variety of approaches out there.  Some earth tube systems are long (hundreds or thousands of feet), others are short (less than 50 feet).  Some propose 4 inch diameter PVC, others are using 24 inch diameter cement tubes.  Various layouts, depths and other design features (weep holes, insulation, flexible connectors, etc) are talked about with great pride or warning.   Many of these designers talk about how their method is the only good method, one particularly rambling blogger warned that any changes from his specific design could only result in disaster.   However, almost all of the designers talk about how successful they were (few have really good data to back it up, but some do and that fraction is growing).  I have concluded that because of dynamic effects (such as fluctuating operating temperatures and moisture levels), the wide range of parameters and the lack of information regarding material properties or other boundary conditions, it may be difficult or impossible to be sure of an optimal earth tube design (at the current state of the art).   However, the wide variety of success indicates that the tolerances for a “pretty good” earth tube design are quite flexible and there is good understanding for how the parameters affect performance.

There has also been sufficient experience to make certain “danger zones” clear.  As far as I can tell, the main dangers include…

  1. Moisture leading to mold and other problems => Make sure to slope your earth tubes and provide good drainage so condensation can exit.   Stay above the water table and keep rain water out.  Be careful with corrugated flex pipe as it could potentially provide lots of places for water to collect.
  2. Blockage rendering the tubes useless => Keep bugs and critters out, design the tubes so they won’t cave in, provide multiple paths as a more robust system, etc.
  3. Flow resistance making it too difficult to move air thru the tubes => system losses (both friction and dynamic losses) add up.  Try to keep the pipe short enough (or large enough diameter) to avoid this problem.  Smoother pipes can be narrower or longer.  Avoid constrictions in the flow, such as two pipes coming into one of the same cross sectional area.  Avoid fittings that try to turn the flow too quickly (such as 90 degree elbows) as these can double the back-pressure…

 

Other factors, such as how much heat is transferred, etc. are just performance details. 😉

In the end, the key to good duct design (earth tubes are buried ducts) is compromise for economy.  The ideal design uses the minimum length of very standard pipes with as few dynamic losses as possible driven by an appropriately sized and affordable fan.

 

The Equations! 

I moved the sections about frictional pressure drop, dynamic pressure drop and Reynolds number to this page.

 

Earth Tube Material: 

When designing an earth tube system, choosing the type of pipe is the most important decision.  I recoomend either solid HDPE pipe or double wall (corrigated outside, smooth inside) HDPE pipe.

You can find more details about Earth Tube Material options here.

 

Earth Tube Length:

Of course, all the parameters (length, diameter, smoothness, path) work together to determine the final performance.   But all other things being fixed, increasing the length of an earth tube provides more length for heat exchange, it also increases the friction and back pressure.  If it is too short, you have less than optimum heat transfer, but it it is too long, it is much harder to get air to flow thru it at all.  At a certain point, the back pressure increases to the point where natural convection can not move the air.  At a more extreme length, the back pressure could reach a level that not even a fan could blow the air thru it.    Cost is a more complex function.  There are certain minimum costs for delivery and getting a crew out to help install the pipes (HDPE pipe requires a professional).    There may also be a minimum order to get decent pricing.  Once you have a truck making a delivery, there is not much difference in delivery cost if it is a full truck or a half truck.   Also, if the pipe needs professional installation, getting someone out for 1 hour usually costs the same as 4.

There are many tools for calculating the length of pipe that you need.   Problem is they usually assume a certain flow rate and don’t take back pressure into account.  They also don’t take the ability of the soil into account.  I will link to some calculators here eventually, but for now I found that rules of thumb based on working examples are just as good.  Passivhaus builders will tell you the diameter tubes that worked for them.  I often see 6 inch pipe used in 250 ft lengths with a fan to keep things moving.

Talking with Adam Bearup recently and he mentioned some experience with the Earth Shelter Project Michigan.  They setup a number of 6 inch diameter PVC earth tubes, each had a fan, but each was only about 50 ft long.  He says the tubes didn’t moderate the temperature of the incoming air for very long after the fans were turned on.  They were probably not long enough for the size of the fans.  The air was moving too quickly thru the tubes and stripped the heat from the tube walls faster than the soil could conduct it.  It was not a thermally stable system.  Even so, the ventilation was insufficient (such a large earth sheltered home would have needed 26 passive tubes running at 175 fpm or 7 tubes at high fan speed of 700 fpm) and so there were problems with humidity, etc.  Adam acknowledged that longer or deeper tubes may have worked better, but at a greater expense.  If he could do it again, he would probably just use a Heat Recovery Ventilator (HRV) instead, the cost would have been a fraction of the cost of the earth tubes.  The HRV is an active system that requires electricity, but at least it is predictable technology.  The HRV exchanges (averages) heat in real time without any thermal storage capacity.

Earth Tube Diameter:  

Again, this is only one of several parameters, but all others held constant, increasing the diameter reduces the back pressure (resistance to flow) by increasing the cross sectional area (π*R2) faster than the perimeter (2π*R) (proportional to surface area).  Hydraulic Diameter is cross sectional area over perimeter and is in the denominator of the D’Arcy equation, which means that increasing diameter reduces pressure losses.   Having a larger diameter means you can get more flow volume at a lower velocity which allows for more heat transfer.  There is also more surface area (for a given length) which also helps increase heat transfer.

Many discussions on this topic will point out that smaller diameter pipe has a larger surface area to flow volume and therefore more heat transfer, but that argument assumes the same flow velocity (reduced flow volume).  If the length and flow volume are held fixed, the larger diameter pipe has greater heat transfer than a smaller diameter pipe.  However if you change the configuration and switch from a single 8 inch to four 4 inch pipes, you would have the same flow volume but double your surface area and therefore increase your heat transfer for the same flow rate.  Changing to the smaller pipes would also increase your back pressure.  Looking at the cost of this configuration, at least for HDPE pipe, the four 4 inch pipe configuration costs 8% less than the single 8 inch pipe configuration.

 

Increasing diameter appears to increase cost at a higher rate than increasing length.  I noticed that prices also increased at a higher rate than the radius and even slightly higher than the cross sectional area.  So while I would probably prefer to have 16 inch diameter pipe, I will probably install 6 inch diameter to get a lower price per inch of cross sectional area, even though this limits my total length.

Certain types of pipe, such as HDPE pipe, have a thickness that is proportional to the diameter.  For instance, HDPE SDR 17 pipe has a wall thickness that is 1/17th of the diameter. The weight of the pipes is therefore proportional to the square of the diameter which means it increases at a faster rate.   This means larger pipes are proportionally heavier (and also harder to bend), and therefore harder to work with, than smaller pipes.  Six inch HDPE SDR 17 pipes are 3.34 lbs/ft, but 8 inch equivalents are 5.66 lbs/ft.  That weight can add up quickly when moving around long sections of pipe.   The insulative properties of the wall would also increase with thickness and reduce heat transfer.

There is a thinner HDPE SDR 32.5 pipe…  Half the thickness of SDR 17 pipe, but it is very non standard and must be ordered from the factory in a large enough batch to make it worth their while (min 1000 ft).  There is also a 6 inch HDPE pipe that comes on a 500ft coil, but I couldn’t find anyone with that in stock either.  I was told that it takes 2 men to wrestle a 4 inch pipe off the coil, but no one I spoke to had actually tried the 6 inch pipe.  One distributor told me that 6 inch coiled pipe has a tendency to kink rather than bend.  The benefit of a coil would have been not needing to hire a professional to fusion weld the pipe.  You could just lay it in one long piece.

Earth Tube Layout: 

The layout of the earth tubes is an important decision.  Some prefer a system with a manifold that separates the flow into parallel lines using T-connections or Y connections.  These connections are usually more expensive than 10 ft of pipe and severely degrade the flow properties.   It is very difficult to balance the flow thru a system of branching connections, and even more so when using a compressible fluid like “air”.  If the system is not balanced, the majority of the flow may go thru only a few of the parallel runs, rendering the rest useless.  I have seen a number of layouts where the pipe used throughout the system was all the same diameter, which constraints the flow rate of the whole system.  Of course there are some benefits.  This type of system is often easier to layout using straight sections of rigid pipe and if one of the pipes is crushed or clogged, at least the other pipes can continue to work.  Often, this system is chosen by people using straight PVC pipe or who have a very limited area to run the earth tubes.

Radiant flooring used to be done this way also, but with smaller diameter PVC pipe.  While water is famous for taking the path of least resistance, It is possible (but still difficult) to “balance” the flow of a relatively “in-compressible” fluid like water, compressible air flow is much more difficult.  Modern radiant flooring tube layouts are typically done with a single PEX or HDPE tube “snaked” across the floor.  In addition to increased performance, this is easier and cheaper than the old branched PVC approach.

Earth tubes can also be snaked using U connections or flexible pipe.  Of course, if more land is available, fewer bends and larger radius curves can be used.    Larger radius curves cause less resistance to the flow, but a straight pipe is actually ideal (if you have the land for it).  However you lay it out, There are many advantages to this serial configuration, including flow uniformity and the ability to clean the pipe if necessary.   (I plan to use a blast of air pressure to fire a bleach soaked Nerf ball thru mine if I ever need to clean it out.)

Another good option is running a number of pipes that are separate for their full length and only come together at the entrance to the home.  Particular configurations can be used that make it easy to connect with a rectangular duct inside the home.  This spreads the tubes out in the earth for maximum heat transfer and storage, but brings it all together for maximum flow volume thru a single opening into the home.

Since I have several acres around my home site, I plan to keep the earth tubes as straight as I can.  I plan to use HDPE pipe that is flexible enough to allow for some bending without any special/expensive connections.  The basic rule of thumb is that you can bend straight HDPE SDR 11 pipe around a radius no less than 50 times the diameter.  Thinner pipe is more flexible, but there is always a chance of kinking if you try to bend it too tightly.  PVC pipe is much less flexible.

 

Earth Tube Depth

Earth tubes work better when they are deeper.  However, after a certain depth, the cost of burying them increases greater than the improvement in performance.  Many “failed” earth tubes are buried less than 3 ft deep.  At that depth, it is probably not worth doing.   Many small excavators have trouble digging below the 8ft depth.  10 ft would be better, but I can understand someone limiting their earth tubes to the depth that their excavator can handle.  Stepping up to the next size excavator could considerably increase the cost.

Working with deeper trenches can be more dangerous, particularly with certain types of soil that tend to cave in.  In that case you would need to dig an even wider trench at further increased costs.

I have seen cases where earth tubes were laid at relatively shallow depths, such as 5ft, but then 1 inch of rigid insulation board was placed 2 ft above the tubes to further separate them from the air temperatures.  This may be a good compromise if the costs of going deeper are prohibitive.

The choice of when to lay pipe is also important.   I know of at least one project where the earth tubes were laid along with the earth cover over the home, which then settled (there is always settling) and damaged most of the PVC earth tubes.   Laying the tubes earlier, along with the foundations, trenched into undisturbed soil, would get them deeper and with much less risk of settling.

 

Camels Nose Heat Exchanger?

Authors such as John Hait recommend putting these tubes close together so that the remaining heat from the exiting air can be transferred to the incoming tube.  His book calls this earth tube design feature a “camels nose” after the well known biological advantage of camels.  I found this excerpt The Biology of Human Survival.

The camel’s nose conserves water by lowering exhaled air temperature and removing water from it. During heat exchange inside the nose, the nasal passages are alternately cooled by inhaled air and warmed by exhaled air. The loss of heat from exhaled air to the nasal passages condenses water much as one’s breath condenses on a cold day, and this moisture is retained in the nose. In addition, the vascular anatomy of the camel’s nose and head provides a counter-current heat exchanger that protects the brain from overheating. A camel’s brain may remain more than 2°C cooler than its body.  ~~~~Claude A. Piantadosi;  The Biology of Human Survival, 2003

 

While this design improves the heat retention efficiency of the system, it may be less desirable from a flow efficiency perspective.  The camel drives the airflow thru his system with a large diaphragm and lungs; but the passive earth tube equivalent is driven by low ΔT based buoyancy.   The theory is that the cold air entering the inlet tube is warmed by the earth, expands and rises due to buoyancy where it enters the home at floor level.  At some point the relatively warm, but used up, air exits home thru the return tubes.  It is cooled by the surrounding earth and is drawn down the tubes by gravity acting on its increasing density.  This is a very low force way to drive the flow and seems to always require fans (augmented passive solar?) to overcome the wall friction of the tubes and actually produce the required fresh-air flow volume thru the home.

The most famous earth sheltered home builders of the natural world are the prairie dogs.  These rodents carefully engineer their tunnels (they live in earth tubes) to provide natural air-conditioning, fresh air, etc.  They passively drive their earth tube system by separating the inlet and outlet by some distance that creates a pressure differential.  Basically, they put the outlet at the top of the hill where the wind-speed is fastest and the air-pressure is lowest.  This low pressure exit creates a suction that actually draws the air up into the earth tubes and thru the system.

This article touches on how prarie dogs use the Bernoulli principle to increase airflow thru their tunnels.  I have read others about how they carefully balance the forks in their tunnels for even distribution and how even their beds of dry grass are kept mold free underground;  I will connect back if I stumble upon articles like that again…

 

Termites and other creatures  start with the Bernoulli principle, but take it a step further by actually constructing solar chimneys.  These use solar energy to heat up the air in the exit pipe which creates expansion and much greater buoyancy than the small temperature difference applied in the Camel-tow method.

This article is about a mall in Zimbabwe modeled on the principles of a termite mound.  This clever approach of copying (mimicking) natures master builders is sometimes referred to as bio-mimicry.

 

When applied to home construction, many PassivHaus experts suggest that your earth tubes should enter habitable space like living rooms and bedrooms to provide fresh air.  This air can move thru the house and then exit from kitchens or bathrooms which require this sort of exhaust vent thru the roof by code anyway.  The idea of venting moisture laden air from these rooms into cool underground pipes is probably not a great one anyway.

So, I do not recommend a Camels Nose arrangement for fresh air earth tubes, but I do think it would be a good idea for my by-passive solar heating earth tubes that must start and stop at the same point anyway.  I plan to run the inlet and outlet tube as near each other as possible for as far as possible so that as much of the exit air heat is transferred to the intake air as possible.  I may also insulate around these when they are outside of the umbrella so that more of the heat is exchanged and not wasted.

Air Intake: 

The air intake is an important component of the design.

Your earth tube needs to be secure to prevent insects and animals from using it as a subway into your home.  In addition to unwanted pests, the tube could bring in odors or germs.  These unwanted guests could also build nests that would inhibit or block the flow of air thru the tubes.  I recommend two levels of screening.  Thicker screen is needed to keep the larger (stronger) animals out.  A second layer of thinner/finer mesh would be used to keep insects out of the tube.   Of course, the ends of the pipe are only a small percentage of the surface and sealing them is not very effective against smaller insects if there are many other holes and joints along the way.   Here again is where HDPE pipe can be a superior option.

Schematic design for a dust settling inlet box for an earth tube intake

Many earth tube designs feature a dust settling box at the inlet.  This is a box that allows dust, pollen and other small particles to settle in a dry well before the air is drawn into the earth tube intake and into the house.   Keeping the dust out also keeps the earth tubes cleaner and less habitable to insects.     The key to this design concept is to let the air in thru a small inlet (about the same area as the earth tubes connected to the box, but then expand the volume rapidly so the air slows down and the particles can settle out of it.   This is most simply done with a hole (covered with screen) in a box in front of the earth tube entrance.  For maximum effect, don’t line up the box inlet and the earth tube inlet.  For reduced pressure loss, create a gradual scoop to transition between the box and your inlet.  If you have a centrifugal fan in your intake box, adding a splitter sheet can help balance the airflow and improve efficiency.  Some keep their tubes even cleaner with the addition of standard furnace filters.  Some have used “electronic air filters” that electrostaticly remove particles from the air without physically getting in the way.

Always keep an eye on system pressure losses.  Intake screens, air filters, even the sudden change in area between the box and the inlet, can cause significant dynamic system losses.

The box can be further enhanced with a wind-scoop to catch air.  This would increase the pressure in the box and help overcome more of the frictional resistance in the pipe.  Of course, this scoop feature should be oriented to catch prevailing winds.

The earth tube intake “box” could be built any number of ways (I plan to build several and experiment with cord-wood, masonry, etc.), but should be sealed against insects and other critters.  They should also have a lid or small door so you can access the earth tube inlet, filter or other features.  I am also considering using some glass block elements to let UV light in for various health reasons.

 

Ventilation Requirements: 

This section about ventilation requirements was broken out into a separate page.

Earth Tubes

Posted on July 24, 2012 by

Earth Tube Basics

Earth Tubes are basically tubes or ducts buried in the earth for the purpose of exchanging heat between the air in the tubes and the earth.  They are often referred to as “Earth Air Heat Exchangers” (EAHX) or “Air-Ground Heat Exchangers” (AGHX) or a variety of other names.   In hot climates (such as Australia) they are often called “cool tubes”, but they work just as well for warming cold air.  They are generally used to moderate the temperature of fresh air entering well sealed homes and are a particularly natural fit for Earth Sheltered homes.

Most home owners who install them realize that, while they are dealing with very ancient and intuitive technology, Earth Tubes are still poorly understood and somewhat “experimental”.  There is much doubt about the performance or cost effectiveness of earth tubes, but I suspect that the poor results are often the result of poor design.  While I am unlikely to put all my “eggs” in the Earth Tube basket, I believe they can be an important component of any good passive solar design.

Bailing out a leaky boat

Trying to heat and could our homes is like bailing out a leaky boat… You can keep bailing or try to plug the holes.

 

In winter, the fresh air outside is cold.  Our homes are full of small cracks (intentional or unintentional) and that cold air finds its way in.  Of course, we use a variety of mechanical systems to heat that air up to a comfortable temperature.  However, that warmed air escapes again pretty quickly and is replaced by new cold air, which is heated up again.  In summer the process is reversed, with expensive machines extracting the heat from our homes while hot air is pouring back in again thru every crack.  It is like trying to bail out a boat that is full of holes, if we didn’t have machines to take care of the work for us, we would never put up with it.  Infiltration is said to be the single greatest waste of energy in the average home.   (The leakage in the average home is equivalent to leaving a 3’x3′ window open all year, it gets even worse when the wind blows.  According to the U.S. Department of Energy, Americans spend 30% of the nations energy adjusting the temperature of the air in their homes.  )

Many PassivHaus builders spend a fortune trying to keep this outside air out, while the earth covered portions of earth shelters are naturally airtight.  Either way, homes need fresh air to be healthy.  If you bring that air directly in from the outdoors, you will need to heat it up to room temperature.  The goal is fresh air exchange without giving up the weather tight advantage completely (and just drilling a big open hole in the wall).   One possible solution is an Air to Air Heat Exchanger  (or Heat Recovery Ventilation (HRV)) that attempts to retain heat by transferring it from the outgoing air to the incoming air.  These units can also filter air and usually include a blower and other active components.  They easily cost several thousand dollars.

Heat recovery ventilation, often with an earth-to-air heat exchanger, is essential to achieve German Passivhaus standards.

The earth tubes are just a lower tech, passive way to do something very similar.  They tap into the heat storage capacity of the earth to moderate incoming air all year long.  They can be used with above ground homes, but are a particularly natural fit for an earth sheltered home.

In many cases, both air to air and air to ground (earth tube) heat exchangers can be used.  It is relatively common to install air to air heat exchangers within the home (such as in the basement) fed tempered air by earth tubes.

Basic Earth Tube Design Basically, in an earth sheltered home with an intake earth tube, the cold winter air is drawn into the tube by convection or fans and absorbs heat from the earth on its way.  By the time it enters the home, its temperature is significantly moderated by the earths temperature, but it usually still needs some additional heat.  This additional energy could come from fossil fuels, a wood stove or passive solar.  Of course, less additional energy would be required than if the air were drawn in directly from the outside.   After being used in the home, the air is eventually expelled (again either due to convection or assisted with fans) thru an exit earth tube where its energy is absorbed back into the earth…

If the exit pipe runs near the entrance pipe (as shown in the above image), exit heat can actually be transferred to the incoming air (similar concept to an HRV).  This is known as a “Camels Nose” heat exchanger.  Other layouts include the use of Bernoulli’s principle and/or a solar chimney to draw the air thru the tubes and home and out the roof.

 

Earth Tube Concerns

A variety of concerns are often stated as reasons not to use Earth tubes.  These range from discussions about cost/benefit analysis to serious health concerns related to mold or radon.  In general, these are due to experiences with improperly installed earth tubes.  This section of this page grew too large and was broken out to a separate page on Earth Tube Concerns.

 

Types of Earth Tubes

While the majority of users only use earth tubes for moderating fresh air, these simple “air to ground heat exchangers” can be used in other ways.  I would like to use Earth Tubes for 3 main purposes.

1) Fresh air moderation; these basic earth tubes bring fresh air into the home (ventilation) and allow stale air to leave.  Passing thru the earth moderates the temperature of the air and reduces the load on the heating or cooling systems.  I created a separate page to discuss ventilation requirements here.

2) By-passive Solar; these earth tubes never enter the home.  Instead they form a loop between the solar hot air collector and the soil under the home.  Solar energy heats the air in the collector, it travels under the home where the energy is absorbed into the soil and then the air returns to the collector to be recharged.  Since it doesn’t matter how stale the air is, a closed loop design where the solar heater reheats the air that just passed thru the loop is the most efficient.

I have an “interesting” idea that I think I can incorporate for minimal incremental cost…  I plan to configure my french drain system to use loops with an inlet and outlet rather than the traditional branched configuration.  This will allow me to push solar heated air thru the tubes to warm up my foundations.  I could use the standard 4 inch HDPE drain pipe, or I could improve the performance with the 50% more expensive 6 inch pipe.  If I try it, I’ll let you know how it performs.

3) Heat Exchange loops within the home; these tubes are relativity short and simply provide additional heat exchange between the air in a room and the surrounding soil.  The loop would connect the a vent near the floor with a vent near the ceiling.  The room air is allowed to pass thru the duct circuit to be moderated by the earth.  For instance, in a warm room, the air near the ceiling may pass into the duct where it would be cooled (and dehumidified) by the cooler earth.  This would reduce the buoyancy of the air, causing it to sink and draw in more warm air.  The cooler air would fall out the bottom vent and help cool the room.  If the room is cooler than the earth, the system would reverse and warm the air.  If the room is better off without the heat exchange, you could just close the vents.

I imagine that it will be important to deal with the condensation that may form or drain out of the tubes.  A tiny weep hole to the earth may be sufficient.

I plan to try at least one of these on my future office.

 

Earth Tube Design

Earth tubes can be designed many ways.  I broke this section on Earth Tube Design out into a separate page.

 

Earth Sheltered Ventilation

Earth Tubes can be used to provide ventilation, but it is important make sure they are sized adequately…   I broke this section on ventilation out into a separate page.

 

Earth Tube Links

I can share some good Earth Tube related links I found here on a separate page.